Yahoo Web Search

Search results

  1. View and Download Predator Generators 4000 Watt Portable Generator owner's manual & safety instructions online. 3200/4000 Watt. Predator Generators 4000 Watt Portable Generator portable generator pdf manual download. Also for: 69728, 69729.

  2. People also ask

  3. View and Download Predator 69728 owner's manual online. 4000 watt portable generator. 69728 portable generator pdf manual download. Also for: 69729.

  4. View and Download Predator 69675 owner's manual & safety instructions online. 3200 RATED WATTS 4000 MAX WATTS. 69675 portable generator pdf manual download. Also for: 69676.

  5. You can troubleshoot your Predator generator. Here are some of the issues you may likely experience with your power-generating unit: • Clogged air filter. You need to regularly clean or replace your air filters if you run your Predator generator in a dusty environment.

    • iMpOrTanT SaFETy inSTruCTiOnS
    • Setup precautions
    • TO prEVEnT SEriOuS inJury, DEaTH, anD GEnEraTOr anD/Or EQuipMEnT DaMaGE FrOM ELECTriC SHOCK anD FirE:
    • Service precautions
    • refueling:
    • Set up
    • air Filter
    • Operation
    • pre-Start Checks
    • Starting the Engine
    • Calculate power Draw:
    • Digital Display Screen
    • Stopping the Engine
    • SHuT OFF
    • Maintenance
    • Cleaning, Maintenance, and Lubrication Schedule
    • Engine Oil Change
    • Oil Drain Cap air Filter Element Maintenance
    • Bracket
    • 3. LuBriCaTiOn:
    • 5. aFTEr STOraGE:
    • Limited 90 Day Warranty (retail)
    • Emissions Control System Warranty
    • ManuFaCTurEr’S WarranTy COVEraGE
    • DEFECTS WarranTy rEQuirEMEnTS:

    WarninG! read all instructions. Failure to follow all instructions listed below may result in fire, serious injury and/or DEaTH. The warnings and precautions discussed in this manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be bu...

    Gasoline fuel and fumes are flammable, and potentially explosive. Use proper fuel storage and handling procedures. Do not store fuel or other flammable materials nearby. Have multiple ABC class fire extinguishers nearby. Operation of this equipment may create sparks that can start fires around dry vegetation. A spark arrestor may be required. T...

    Follow parallel Kit instructions provided with Kit for connection and use of a parallel Kit. Only connect two identical Inverter Generators together using a Parallel Kit. Connect Parallel Kit only to terminals marked “Parallel Outlets” on the front of the Generator.

    Before service, maintenance, or cleaning: unplug all devices from the generator. Turn the Combination Switch to its “OFF” position. allow the engine to completely cool. Then, remove the spark plug cap from the spark plug. Keep all safety guards in place and in proper working order. Safety guards include muffler, air cleaner, mechanical guards, and...

    Do not refill the fuel tank while the engine is running or hot. Do not smoke, or allow sparks, flames, or other sources of ignition around the equipment, especially when refuelling. Do not fill fuel tank to the top. Leave a little room for the fuel to expand as needed. Refuel in a well-ventilated area only. Wipe up any spilled fuel and allow exc...

    read the EnTirE iMpOrTanT SaFETy inFOrMaTiOn section at the beginning of this manual including all text under subheadings therein before set up or use of this product. TO prEVEnT SEriOuS inJury anD FirE: Operate only with proper spark arrestor installed. Operation of this equipment may create sparks that can start fires around dry vegetation. a sp...

    Figure C: Generator rear and interior Starter Handle Oil Drain Bolt Oil Fill Cap

    read the EnTirE iMpOrTanT SaFETy inFOrMaTiOn section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

    Inspect Engine and Generator looking for damaged, loose, and missing parts before set up and starting. If any problems are found, do not use equipment until fixed properly. Checking and Filling Engine Oil nOTiCE: Generator is shipped without engine oil. Engine’s crankcase MuST be filled with oil before first use. your Warranty is VOiD if the E...

    Before Starting the Engine inspect the generator and engine. Disconnect all electrical loads from the generator. Fill the engine with the proper amount and type of both stabilizer-treated unleaded gasoline and oil.

    Power draw can be calculated by multiplying volts and amps. The resulting number is wattage. Never exceed the running wattage for the Generator or any outlet amperage rating. Refer to appliance/tool owner’s manuals to determine the wattage of electrical load devices. Long power cords and extension cords draw additional power. Keep cord length at ...

    The Display Screen can be used to monitor the operating status of the Generator. Use the Display Control Button to scroll through the following indicators: V – Voltage A – Amperage VA – Volt Amps / Watts Hour – current run time and accumulative run time

    To stop the Engine in an emergency, turn the Combination Switch OFF. OFF run STarT EMErGEnCy

    Under normal conditions, use the following procedure to shut off the Generator: Turn all electrical load devices off and unplug them from the Generator. If the Economy (ESC) Switch is ON, turn it to the OFF position. Turn the Combination Switch OFF. unplug Loads

    WarninG TO prEVEnT SEriOuS inJury FrOM aCCiDEnTaL STarTinG: Turn the Combination Switch of the equipment to its “OFF” position, wait for the engine to cool, and disconnect the spark plug cap before performing any inspection, maintenance, or cleaning procedures. TO prEVEnT SEriOuS inJury FrOM EQuipMEnT FaiLurE: Do not use damaged equipment. if abno...

    note: This maintenance schedule is intended solely as a general guide. If performance decreases or if equipment operates unusually, check systems immediately. The maintenance needs of each piece of equipment will differ depending on factors such as duty cycle, temperature, air quality, fuel quality, and other factors. note: The following procedur...

    CauTiOn! Oil is very hot during operation and can cause burns. Wait for engine to cool before changing oil. note: Make sure Generator is level when adding oil to prevent overfilling which could cause engine damage. 8. Check the oil level. The oil level should be up to the edge of the hole as shown.

    Loosen two screws and remove the Access Panel on the left side of the Generator. access panel Remove the Air Filter Cover and the air filter elements and check for dirt. Clean as described below.

    5. Clean the Spark Arrestor using a wire brush (sold separately). Replace arrestor if damaged. 6. WarninG! TO prEVEnT SEriOuS inJury FrOM aCCiDEnTaL BruSH FirE, secure Spark arrestor back in place immediately after cleaning and before further operation. Spark plug Maintenance Loosen two screws and remove the Access Panel on the left side of the Ge...

    Change engine oil. Clean out area around spark plug. Remove spark plug and pour one tablespoon of engine oil into cylinder through spark plug hole. Replace spark plug, but leave spark plug cap disconnected. Pull Starter Handle to distribute oil in cylinder. Stop after one or two revolutions when you feel the piston start the compression stroke (...

    Before starting the engine after storage, keep in mind that untreated gasoline will deteriorate quickly. Drain the fuel tank and change to fresh fuel if untreated gasoline has been sitting for a month, if treated gasoline has been sitting beyond the fuel stabilizer’s recommended time period, or if the engine does not start.

    Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misu...

    The California Air Resources Board, the United States Environmental Protection Agency, and Harbor Freight Tools (HFT) are pleased to explain the exhaust and evaporative emissions (“emissions”) control system warranty on your [Model Year] Small Off-Road Engine, in addition to the Retail Warranty above. In California, new equipment that uses small of...

    The exhaust and evaporative emissions control system on your small off-road engine is warranted for two years. If any emission-related part on your small off-road engine is defective, the part will be repaired or replaced by HFT.

    The warranty period begins on the date the engine or equipment is delivered to an ultimate purchaser. The warranty period is two years. HFT warrants to the ultimate owner and each subsequent owner that the engine or equipment is: Designed, built, and equipped so as to conform with all applicable regulations adopted by the Air Resources Board; and F...

    • 6MB
    • 28
  6. This manual contains important instructions that should be followed during installation and maintenance of the Generator and any batteries. Set up precautions.

  7. Initial Tool Set Up/Assembly Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. SAFETY TO PREVENT SERIOUS INJURY: Operate only with proper spark arrestor installed.

  1. People also search for